Software Specifications – Sound Level Meter Software for 2250 Light BZ-7130
Conforms with the following National and International
Standards:
IEC 616721 (2013) Class 1
IEC 60651 (1979) plus Amendment 1 (1993– 02)
and Amendment 2 (200010), Type 1
IEC 60804 (200010 ), Type 1
DIN 45657 (199707)
ANSI S1.4–1983 plus ANSI S1.4 A1985
Amendment, Type 1
ANSI S1.431997, Type 1
Note: The International IEC Standards are adopted as
European standards by CENELEC. When this
happens, the letters IEC are replaced with EN and the
number is retained. 2250 Light also conforms to these
EN Standards
Input
CORRECTION FILTERS
For Microphone Types 4950, 4952+EH-2152, 4952
and 4184-A:
Correct the frequency response to compensate for
sound field and accessories
Accessories (Type 4950 only): None or Windscreen
UA-0237
Sound Field: Free-field or Diffuse-field (for Types
4952 and 4184-A only: 0° (Top) reference direction
and 90° (Side) reference direction)
Analysis
DETECTORS
Parallel Detectors: On every measurement:
A- or B-weighted: (Switchable) broadband detector
channel with three exponential time weightings (Fast,
Slow, Impulse), one linearly averaging detector and
one peak detector
C- or Z-weighted: (Switchable) as for A- or B-
weighted
Overload Detector: Monitors the overload outputs of
all the frequency weighted channels
MEASUREMENTS
X = frequency weightings A or B
Y = frequency weightings C or Z
V = frequency weightings A, B, C or Z
U = time weightings F or S
Q = exchange rate 4, 5 or 6 dB
N = number between 0.1 and 99.9
For Storage: Full statistics
For Display and Storage:
Weather Data (requires connection to a weather
station):
Wind Dir. avg.
Wind Dir. min.
Wind Dir. max.
Wind Speed avg.
Wind Speed min.
Wind Speed max.
Amb. Temperature
Amb. Humidity
Amb. Pressure
Rainfall
Only for Display as Numbers or Quasi-analog Bars
Start Time Stop Time Overload %
Elapsed Time L
Xeq
L
Yeq
L
XE
L
YE
L
Ceq
–L
Aeq
L
XSmax
L
XFmax
L
XImax
L
YSmax
L
YFmax
L
YImax
L
XSmin
L
XFmin
L
XImin
L
YSmin
L
YFmin
L
YImin
L
XIeq
L
YIeq
L
AIeq
–L
Aeq
L
AFTeq
L
AFTeq
–L
Aeq
Time Remaining
L
ep,d
L
ep,d,v
E
Dose% Proj. Dose% #VPeaks
(>NNNdB)
#VPeaks
(>137dB)
#VPeaks
(>135dB)
L
Vpeak
T
Vpeak
L
avUQ
TWA
TWA
v
DoseUQ% Proj. DoseUQ%
L
Aeq,T1,mov,max
L
Aeq,T2,mov,max
L
Ceq,T1,mov,max
L
Ceq,T2,mov,max
L
eq,T1,mov,max
L
eq,T2,mov,max
L
XS
L
XF
L
XI
L
YS
L
YF
L
YI
L
XS(SPL)
L
XF(SPL)
L
XI(SPL)
L
YS(SPL)
L
YF(SPL)
L
YI(SPL)
L
Vpeak,1s
L
AN1
or L
AUN1
L
AN2
or L
AUN2
L
AN3
or L
AUN3
L
AN4
or L
AUN4
L
AN5
or L
AUN5
L
AN6
or L
AUN6
L
AN7
or L
AUN7
Std.Dev.
L
Aeq,T1,mov
L
Aeq,T2,mov
L
Ceq,T1,mov
L
Ceq,T2,mov
L
eq,T1,mov
L
eq,T2,mov
Vue de la page 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 211 212

Commentaires sur ces manuels

Pas de commentaire